All services

IITE · IEE · ITE · ITE Euskadi

Building inspection (ITE and IEE): what it is, when it is due and who signs it

The building inspection is how the owners show the state of their building. The State sets no single age or calendar: each autonomous community and each town hall sets its own. This guide gathers those rules and links each community's page.

Guide reviewed in October 2026

What the building inspection is

The owner of a building has a duty to keep it in the legal conditions of safety, health, universal accessibility and decorum (TRLSRU, art. 15.1.b). The building inspection is how that is shown: the Administration may require the owners of homes in collective residential buildings to prove the building's state of conservation, its compliance with the universal accessibility rules and its energy efficiency (TRLSRU, art. 29.1).

Depending on where the building stands, the inspection goes by a different name: ITE (inspección técnica de edificios), IEE (informe de evaluación del edificio, the building assessment report), IITE in Catalonia (informe de la inspecció tècnica de l'edifici), IEEV.CV in the Valencian Community (informe de evaluación del edificio de viviendas) or the ITE in Euskadi, which in Basque is the EIT (Eraikinen Ikuskaritza Teknikoa).

ITE and IEE

State law does not define the ITE: each autonomous community or town hall regulates it, through its own norm or ordinance.

The IEE was created by Ley 8/2013, which gave it a state calendar and content and said who signed it. The Constitutional ruling STC 143/2017 declared those provisions void, and with them sections 2 to 6 of article 29, article 30 and the second transitional provision of the TRLSRU: the State has no competence to impose the assessment of conservation and accessibility, nor to regulate the instruments that check those duties. Each community now decides.

Where the IEE survives, the regional norm sets what it covers. The Community of Madrid keeps both: the City of Madrid's ITE and the IEE, which covers conservation, accessibility and an energy performance certification already entered in the register. The Valencian Community has the IEEV.CV, which covers conservation, accessibility and energy.

Which buildings need one, and how often

There is no single age for the whole of Spain: each community and each town hall sets its own. Among the communities in the table, the age that triggers the first inspection is 30 for the City of Madrid's ITE, 45 in Catalonia and 50 for Madrid's IEE, in the Valencian Community and in Euskadi. In Andalusia it is also 50 by default, unless the municipal ordinance sets another term.

After that, the inspection is repeated. In Madrid, both the ITE and the IEE every 10 years, as in Euskadi; in the Valencian Community the IEEV.CV is valid for 10 years from its entry in the register; in Andalusia, by default, at least every 10 years, unless the ordinance sets another term; and in Catalonia the validity depends on the worst grade of the defects: 10, 6 or 3 years.

Age is not the only reason: in Catalonia, the Community of Madrid, the Valencian Community and Euskadi a building of any age has the inspection done to apply for public rehabilitation aid. And every building obliged to the ITE or an equivalent inspection must have an energy performance certification (Royal Decree 390/2021, art. 3.1.f).

The inspection in each community

The table sums up, for each community with a page of its own, what the report is called, when the first inspection is due and how often it is repeated; the community's name leads to its page, with the norm and its sources.

The building inspection in each community: report, first inspection and period
CommunityReportFirst inspectionPeriod
CataloniaIITEBefore the building turns 4510, 6 or 3 years, by the worst grade
Community of MadridITE (City of Madrid) and IEEITE: the year after turning 30; IEE: within 5 years of turning 50Every 10 years
AndalusiaITEBy default, the year after turning 50, unless the municipal ordinance sets another termAt least every 10 years, unless the ordinance sets another term
Valencian CommunityIEEV.CVBy 31 December of the year after turning 50Valid for 10 years from its entry in the register
Basque CountryITE (EIT)Within the year after turning 50Every 10 years
GaliciaIEE (IAE)Within the year after turning 50Valid 10 years from its signature
Castile and LeónITEThe year after turning 40, depending on the municipality’s sizeEvery 10 years
AragonITE (periodic inspection)Buildings over 50 years old in municipalities over 25,000 inhabitants; Zaragoza, the year after turning 50Every 15 years; in Zaragoza, every 10

In the other communities, the age and the period are set by the regional norm or the town hall's ordinance: check both before planning the inspection.

Who may carry it out and sign it

Since STC 143/2017 declared article 30 of the TRLSRU void, state law no longer says who may sign an IEE: each community's norm does. The same goes for the ITE, which each community or town hall regulates. Before you take on a job, check what the norm where the building stands asks for.

Every regime in the table calls for a técnico competente, a competent technician under the Building Act (LOE). Some add conditions: in Catalonia the technician must hold liability insurance; in Euskadi the technician must hold it and also be independent; for Madrid's IEE and the Valencian Community's IEEV.CV the technician signs a declaración responsable, and for Madrid's IEE the owner signs it too.

What the inspection results in

The result depends on the regime. The City of Madrid's ITE and Andalusia's end in a favorable or desfavorable (unfavourable) report. In Catalonia the technician grades the defects and the Administration resolves the building's aptitude from those grades. In Euskadi the works are ranked in five grades of urgency: immediate, very urgent, urgent, medium term and maintenance. In the Valencian Community there is no pass or fail: the IEEV.CV sets out the interventions the building calls for, whether maintenance, medium-term or urgent.

When the inspection finds defects, the procedure goes on. In Andalusia a desfavorable report sets a deadline for the works. In Catalonia, once the IITE is handed in, the rehabilitation programme follows: within a year, or within six months if a defect is serious. In Euskadi the owners accredit the correction within three months of finishing grade 1 to 3 works.

The duty of conservation the inspection starts from has a reach that state law sets: it extends up to half the current value of an equivalent new building (TRLSRU, art. 15.3).

Who hands it in, and where

The owners or the community of owners hand the inspection in. In Catalonia they hand it in at the Agència de l'Habitatge, preferably online, and the IITE lapses if it is not handed in within four months of its date. In Madrid the ITE goes to the city's registry, and the IEE to the town hall within three months of the last visit, which forwards it to the regional register. In Andalusia it goes to the town hall, which keeps a public register. In the Valencian Community the IEEV.CV is entered electronically in the regional IEEV.CV register within three months of the inspection. In Euskadi the community of owners hands it in at the town hall, which enters it in the Registro de ITE de la CAE.

Entry in the register does not mean the Administration agrees with the content: Madrid's norm says so for the IEE and Valencia's for the IEEV.CV. And the report accepted is produced in the administration's own tool: the Agència de l'Habitatge's in Catalonia, the Community of Madrid's application for the IEE, the Generalitat's free IEEV.CV application in the Valencian Community and Euskoregite, the Basque Government's application, in Euskadi. In Andalusia it follows the town hall's model or, where the town hall has none, the professional college's (colegio profesional).

What an ITE costs

There is no reference fee: the Professional Associations Act (Ley 2/1974) forbids the colegios to set indicative fee scales or any other rule on fees (art. 14). So no colegio publishes figures and each technician sets their own fee. What does circulate are the ranges quote-request portals publish, they close this section, with their source and date, after what makes one inspection more work than another.

Built area and number of dwellings; the building's age and state; access to roofs and façades; tests or catas (trial openings) when the technician needs them; whether the regime asks for accessibility and energy, as the IEE does, or for conservation only; and whether the building also needs an energy performance certification, which every building obliged to the ITE or an equivalent inspection must have (Royal Decree 390/2021).

Ranges published by third parties, read on 1 November 2026 and copied as each page shows them, in Spanish notation (1.000 € is one thousand euros). They are market observations, not the fees of whoever publishes this guide nor a price recommendation.

How the technician prepares the inspection

A well-prepared inspection starts before the visit. This is the list worth going through with the owners:

  1. The cadastral reference and the year of construction. In Catalonia the age counts from the date in the cadastre.
  2. The previous ITE or IEE, if there is one, and its result.
  3. The energy performance certification. Madrid's IEE needs it already entered in the register, and Valencia's IEEV.CV attaches one, which is not the one required to sell or rent.
  4. The regime that applies and the official model or tool the report is produced in.
  5. The common elements to visit (roofs, façades, structure, installations) and how to reach them.
  6. Each defect recorded with the element it affects, a photo and its grade.

Building inspection visit checklist

An indicative list to prepare the professional's visit. It is not the inspection report, which is produced with the tool or the template each administration sets.

Documents to gather

  • Cadastral reference and year of constructionIn Catalonia, the building's age counts from the date in the cadastre.
  • Previous inspectionThe previous ITE or IEE, if there is one, and its result.
  • Energy performance certificationWhether the building has one and whether it is registered: the Madrid IEE needs it already registered.
  • Applicable regimeThe regional rule or the municipal ordinance that applies, and the template or tool the report is produced with.

Elements to visit

  • RoofsHow to reach them and who provides access.
  • FaçadesThe street and courtyard façades, and where they can be seen from.
  • StructureThe places where the structure is exposed: basements, garages, voids.
  • Building servicesThe plant rooms and service shafts of the shared installations, and their keys.
  • Access and keysWho opens the common areas and the homes to visit, and when.

Each deficiency

  • Element affectedThe element and where it is in the building.
  • PhotoOne photo of each deficiency, with a reference to locate it.
  • GradeThe deficiency's grade, if the applicable regime grades them.

Equipment for the visit

  • Camera or phoneCharged, with room for the photos of the whole visit.
  • MeasuringA tape or laser meter to locate and measure the deficiencies.
  • TorchFor basements, roof voids and service shafts.

Get the editable Word version

We email you a link to download it and adapt it to your work.

Controller: ArquiFlow. Purpose: to send you the document and, only if you tick the box and confirm it from the email, ArquiFlow news. Legal basis: your request and, for the news, your consent. Recipients: our email provider. Rights: access, rectification, erasure and the others explained in the privacy policy.

If you own the building: what to ask your technician

If you own a flat or manage a residents' association, the owners commission the inspection and a technician carries it out. Before you hire one, ask for this:

  • Which report the building needs and when it is due, under the regional rules and the city ordinance.
  • A quote that lists the common elements they will inspect — roofs, façades, structure, services — and whether it covers accessibility and energy efficiency.
  • The list of documents they need: the cadastral reference, the previous ITE or IEE, if there is one, and the energy performance certification.
  • A report that describes each defect with the element it affects, a photo and its grade, so you know what to fix first.
  • Who hands the report in and where, and what deadlines remain if works are needed.

The inspection report, in ArquiFlow

You choose the regime — Catalonia's IITE, the IEE (building assessment report), a municipal ITE or the Euskadi ITE (Decreto 117/2018) — and the report asks for its fields. You grade each defect by building element and, on an IITE, see the indicative rating that follows under Decret 67/2015. You sign it in the app and email it as a PDF.

  1. You choose the regime

    Catalonia's IITE, the IEE (building assessment report), a municipal ITE or the Euskadi ITE (Decreto 117/2018). The report shows the building's details and the fields that regime asks for.

  2. You record the defects

    Each observation in the report carries the building element it affects: façades, roofs, structure, installations…

  3. You grade them

    Each defect carries its grade: minor, important, serious or very serious.

  4. And you see the indicative rating

    On an IITE, the report shows the most serious defect and the indicative certificate it would lead to under Decret 67/2015, given whether the precautionary measures were carried out. The certificate itself is issued by the Administration.

Good to know

  • Each regime's own fields

    The report prints only the chosen regime's fields. If you switch regime, what you had already written is kept.

  • An indicative rating nobody types by hand

    The indicative rating is worked out from the graded defects and the precautionary measures, so it cannot contradict what the report says.

  • The report is the technician's

    The report sets out your inspection and your assessment as the signing technician. Taking it to the competent authority is the owner's responsibility.

  • Signed and sent from the app

    You sign the issued report in the app and email it as a PDF to the owner and anyone else who needs it.

Frequently asked questions

Is the ITE compulsory throughout Spain?

There is no single state calendar. Ley 8/2013 created the IEE with a state calendar, but the Constitutional ruling STC 143/2017 declared those provisions void: the State has no competence to impose the assessment of conservation and accessibility. Today each autonomous community and each town hall sets the obligation, the age and the period, so it depends on where the building stands.

What is the difference between the ITE and the IEE?

State law does not define the ITE: each community or town hall regulates it. The IEE is the building assessment report, and where it exists, the regional norm sets what it covers. The Community of Madrid keeps both, the City of Madrid's ITE and the IEE; the Valencian Community has the IEEV.CV; and elsewhere the community's own norm says.

How often must the ITE be done?

It depends on the community. In Madrid and Euskadi, every 10 years; in the Valencian Community the IEEV.CV is valid for 10 years from its entry in the register; in Andalusia, by default at least every 10 years, unless the municipal ordinance sets another term; and in Catalonia, by the worst grade of the defects: 10, 6 or 3 years.

Which inspection regimes does it cover?

Catalonia's IITE, the IEE (building assessment report), the municipal ITE and the Euskadi ITE (Decreto 117/2018). Each shows its own fields, and the indicative rating is worked out only on an IITE, because it follows Decret 67/2015.

Does ArquiFlow hand the report to the Administration?

No. In ArquiFlow you write the report, sign it and send it as a PDF. Taking it to the competent authority is the owner's responsibility, and the certificate is issued by the Administration: the one the report shows is indicative.

Can I change the regime later?

Yes, until the report is issued. What you had written for the other regime is kept, though only the chosen regime's fields are printed.

Try ArquiFlow on your next project